<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-17 15-59-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 53 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 4.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 67 kHz 6061 0,3630
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,0 dBr 4,66 dBr 6,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 67 kHz MIN: 12 kHz % above 76 kHz: 0,3630 Acquired: 2025/08/17 15.58.50 Total samples: 6061 Equivalent time: 0:05:03 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300
FM Scope MAX: 6,3 dBr MIN: 2,0 dBr AVE: 4,66 dBr % above 12,2 dBr: 0,0 Last value: 6,1 dBr (2025/08/17 15.58.50) 15.44 15.46 15.48 15.50 15.52 15.54 15.56 15.58 0 2 4 6 Pm [dBr]